| Railway Cables | |||||||||||||
Axle Counter Cable
RT/F3 D & S & B type Axle Counter Cable
Applications
The cables are designed for transmission of signals up to 90 kHz in axle counter train detection systems.
Standards
● RT/E/PS/00031
![]() |
![]() |
![]() |
Construction
- Conductors: Tinned copper, 0.9/1.4 mm nominal diameter.
- Insulation: Solid polyethylene.
- Cabling Element: Two insulated conductors are twisted together to form a pair.
- Stranding: Pairs are helically stranded in concentric layers.
- Filling: Cable core interstices are filled with a low-permitivity compound. Unfilled cables option can be offered upon request.
- Core Wrapping: Plastic tape(s) with overlapping.
- Moisture Barrier: One laminated sheath made of aluminium tape coated with PE-Copolymer on at least one side is applied with longitudinally overlap.
- Inner Sheath (for S/B type): Polyethylene or LSZH fire retardant compound.
- Mechanical Protection (for S/B type): One corrugated steel tape or brass tape is longitudinally applied with overlap. Unarmoured cables option can be offered upon request.
- Outer Sheath: Polyethylene or LSZH fire retardant compound. Ruggedised PE sheath compound can be offered upon request.
Type Codes
F1 class: Non LSZH cables.
F5 class: Unfilled cables
D type: Unarmoured types
R type: Ruggedised PE sheath
S type: Steel tape armoured types
B type: Brass tape armoured types
E1, E2 & E3 types: 3 different induction protection levels available.
Electrical Characteristics at 20℃
Nominal Conductor Diameter |
mm |
0.9 |
1.4 |
Nominal Conductor Cross Section |
mm2 |
0.63 |
1.5 |
Maximum Conductor Resistance |
Ω/km |
30.0 |
12.5 |
Minimum Insulation Resistance @500 V DC (1min) |
MΩ.km |
5000 |
5000 |
Nominal Conductor Capacitance @800Hz/1000Hz (AC) |
nF/km |
42+3 |
47+3 |
Dielectric Strength, conductor to screen (DC voltage 2mins) |
V |
3000 |
3000 |
Maximum Average Attenuation |
|
|
|
@1.0KHz |
dB/km |
0.73 |
0.45 |
@2.4KHz |
dB/km |
1.10 |
0.62 |
@40KHz |
dB/km |
2.88 |
1.77 |
@90KHz |
dB/km |
3.70 |
2.41 |
@1.024MHz |
dB/km |
11.2 |
7.45 |
Minimum Average Near-end Crosstalk |
|
|
|
@1.0KHz |
dB/km |
60 |
60 |
@2.4KHz |
dB/km |
60 |
60 |
@40KHz |
dB/km |
50 |
50 |
@90KHz |
dB/km |
50 |
50 |
@1.024MHz |
dB/km |
35 |
35 |
Mechanical and Thermal Properties
- Minimum Bending Radius: 7.5xOD (unarmoured); 10xOD (armoured)
- Temperature Range: -30℃ to +60℃(during operation); -10℃ to +60℃(during installation)
Core Identification:
| Pair Number | A Wire |
B Wire |
Pair Number |
A Wire |
B Wire |
1 |
WHITE |
BLUE |
13 |
YELLOW |
GREEN |
2 |
WHITE |
ORANGE |
14 |
YELLOW |
BROWN |
3 |
WHITE |
GREEN |
15 |
YELLOW |
GREY |
4 |
WHITE |
BROWN |
16 |
VIOLET |
BLUE |
5 |
WHITE |
GREY |
17 |
VIOLET |
ORANGE |
6 |
RED |
BLUE |
18 |
VIOLET |
GREEN |
7 |
RED |
ORANGE |
19 |
VIOLET |
BROWN |
8 |
RED |
GREEN |
20 |
VIOLET |
GREY |
9 |
RED |
BROWN |
21 |
TURQUOISE |
BLUE |
10 |
RED |
GREY |
22 |
TURQUOISE |
ORANGE |
11 |
YELLOW |
BLUE |
23 |
TURQUOISE |
GREEN |
12 |
YELLOW |
ORANGE |
24 |
TURQUOISE |
BROWN |
Two pair cables laid up in quad formation colour coded in rotation, Orange, White, Green, Black
Dimensions and Weight
AJ -2Y(L)2Y n x2x 0.9/1.4 Cables
| Cable Code | Number of Pairs |
Nominal Sheath Thickness |
Maximum Overall Diameter |
Nominal Weight |
0.9mm conductor, 1.55mm Insulated wire |
||||
RS/RT/F3-D-2Y(F)(L)2Y-2P0.9 |
2 |
2.4 |
13.2 |
210 |
RS/RT/F3-D-2Y(F)(L)2Y-10P0.9 |
10 |
2.4 |
21.6 |
530 |
RS/RT/F3-D-2Y(F)(L)2Y-12P0.9 |
12 |
2.4 |
24.8 |
580 |
RS/RT/F3-D-2Y(F)(L)2Y-19P0.9 |
19 |
2.4 |
31.2 |
800 |
RS/RT/F3-D-2Y(F)(L)2Y-24P0.9 |
24 |
2.4 |
33.8 |
980 |
1.4mm conductor, 2.2mm Insulated wire |
||||
RS/RT/F3-D-2Y(F)(L)2Y-2P1.4 |
2 |
2.4 |
23.4 |
320 |
RS/RT/F3-D-2Y(F)(L)2Y-10P1.4 |
10 |
2.4 |
30.0 |
910 |
RS/RT/F3-D-2Y(F)(L)2Y-12P1.4 |
12 |
2.4 |
32.0 |
1101 |
RS/RT/F3-D-2Y(F)(L)2Y-19P1.4 |
19 |
2.4 |
37.3 |
1450 |
RS/RT/F3-D-2Y(F)(L)2Y-24P1.4 |
24 |
2.4 |
42.3 |
1780 |
AJ-2Y(L)2YB2Y n x2x 0.9/1.4 Cables
Cable Code |
Number of Pairs |
Nominal Sheath Thickness |
Maximum Overall Diameter |
Nominal Weight |
|
Inner |
Outer |
||||
0.9mm conductor, 1.8mm Insulated wire |
|||||
RS/RT/F3-S-2Y(L)2YB2Y-2P0.9 |
2 |
2.2 |
2.4 |
22.0 |
399 |
RS/RT/F3-S-2Y(L)2YB2Y-10P0.9 |
10 |
2.2 |
2.4 |
30.4 |
880 |
RS/RT/F3-S-2Y(L)2YB2Y-12P0.9 |
12 |
2.2 |
2.4 |
33.6 |
963 |
RS/RT/F3-S-2Y(L)2YB2Y-19P0.9 |
19 |
2.2 |
2.4 |
40.0 |
1312 |
RS/RT/F3-S-2Y(L)2YB2Y-24P0.9 |
24 |
2.2 |
2.4 |
42.6 |
1626 |
1.4mm conductor , 2.7mm Insulated wire |
|||||
RS/RT/F3-S-2Y(L)2YB2Y-2P1.4 |
2 |
2.2 |
2.4 |
32.2 |
608 |
RS/RT/F3-S-2Y(L)2YB2Y-10P1.4 |
10 |
2.2 |
2.4 |
38.8 |
1510 |
RS/RT/F3-S-2Y(L)2YB2Y-12P1.4 |
12 |
2.2 |
2.4 |
40.8 |
1827 |
RS/RT/F3-S-2Y(L)2YB2Y-19P1.4 |
19 |
2.2 |
2.4 |
46.1 |
2380 |
RS/RT/F3-S-2Y(L)2YB2Y-24P1.4 |
24 |
2.2 |
2.4 |
51.1 |
2954 |